Technical Center
Air compressor knowledge, troubleshooting, maintenance and calculators
Knowledge Base
In-depth knowledge base, technical manuals and principles.
Troubleshooting
Fix common issues: overheating, low pressure, oil leaks, noise.
Maintenance Guide
Scheduled maintenance per manufacturer recommendations.
Calculators
9 tools: flow, power, piping, ROI, heat recovery.
Tech Videos
Repair, maintenance, installation video guides.
Project Photos
Photo gallery of real installation and repair projects.
Technical Articles
268 articles
TroubleshootingMaintenance of Hitachi 22Kw air compressor
Note:- Before servicing , carefully read the safety instructions.- Be sure to turn off the power when performing inspection or maintenance. Otherwise, these tasks will cause accidents such as electrical short circuits. - When machine parts need to be removed or removed to ensure pressure release to the surrounding air pressure. High pressure inside the machine will blow out when removing belts, hoses, or other accessories and can cause unwanted accidents.
TroubleshootingHanbell machine maintenance schedule
Oil-filled screw air compressors usually the output compressed air will contain a small amount of oil mixed within the compressed air, this compressed air stream is cooled when passing through the cooling coil and in the refrigerated dryer (for machines with integrated dryers) it will form condensate containing oil. Depending on the needs of the user, some manufacturers of Atlas copco air compressors have an additional oil processor installed, called OSCi for short. The OSCi is a condensate treatment device designed to separate the oil fraction from the condensate and absorb the oil into a replacement oil filter, which helps prevent environmental pollution. OSCi It has the ability to break down and absorb stable emulsions. OSCi is not affected by impact or vibration because it uses a filter common to all types of drains. The rinse water will meet all environmental requirements. The OSCi is installed inside the compressor housing.
TroubleshootingAir dryer maintenance
Air dryer maintenance time depends on operating mode and ambient conditions. The time period below is understood as a general recommendation.
TroubleshootingTroubleshooting Quincy air compressors
Only use good quality spare parts to ensure proper operation when using the Quincy air compressor.
TroubleshootingTechnical specifications of Sullair TS32 air compressor
Oil should be changed every 8000 hours or once a year. Oil should be changed more frequently in some cases with operating conditions such as high ambient temperatures
TroubleshootingHIGHLIGHTS OF HANBELL AIR COMPRESSOR
During the use of the air compressor, the operator needs to have appropriate air compressor maintenance methods to avoid damage and ensure the machine's performance and operating capacity. Here, Minh Phu would like to introduce to readers some maintenance methods for Hanshin GRH air compressors as well as other air compressor brands as follows:
TroubleshootingNotice on Kyungwon compressor screen part 1
Lighting: The dryer is not equipped with local lighting as it is designed for indoor use. Sufficient lighting in the workplace according to actual assessment and factory regulations.
TroubleshootingStart-up inside the Kaeser ASK series air compressor
- The operator should seek instructions for the safe operation of the Kaeser ASK series machine.- Instructional warnings are placed before potentially dangerous tasks.- Failure to follow the operating safety and warning instructions can cause serious injuries.
TroubleshootingMaintenance of Hitachi 22Kw air compressor
Note:- Before servicing , carefully read the safety instructions.- Be sure to turn off the power when performing inspection or maintenance. Otherwise, these tasks will cause accidents such as electrical short circuits. - When machine parts need to be removed or removed to ensure pressure release to the surrounding air pressure. High pressure inside the machine will blow out when removing belts, hoses, or other accessories and can cause unwanted accidents.
TroubleshootingProblem with Hitachi air compressor series 2000 model OSP-110S5AL shutting down
Note: In case an alarm occurs, handle it before restarting the machine. Ask your dealer or specialized companies if anything is unclear.
TroubleshootingEquivalent conversion table of Kobelco air filter
Kobelco screw air compressor air filter spare parts. Kobelco air compressor air filters not only have a cool and sophisticated appearance but also have a long lifespan of about 2000 hours. Designed to ensure 100% clean compressed air, bringing high efficiency and minimizing costs for users.
TroubleshootingConversion table of Hitachi oil separator to Airpull oil separator-OEM oil separator
Note: 1. The separator filter should be replaced when the pressure difference between the two ends reaches 0.15Mpa. In addition, differential pressure reading 0, low air flow or filter core error. In the above conditions, the filter should be replaced with a new one.2. In general, the cup should be replaced after 4000 hours of use. Replacement time will be shorter if used in dusty environments. 3. When installing the oil return tube, you must attach the tube to the bottom of the filter element. To prevent electrostatic discharge of the metal connection to the oil tank shell.